Leading Manufacturer of swing check valve (flanged / grooved type) and foam concentrate control valve from Faridabad.
Get Latest Price
| Valve Size | 2'' to 12 inch |
| Body Material | Ductile Iron |
| End Connection | Flange / Groove |
| Pressure Rating | PN16 |
| Seat Material | Metal Seated |
| Suitable Media | Water / Foam |
| Pressure | 300 psi |
| Surface Finish | epoxy coated |
| Usage/Application | industrial |
| Country of Origin | Made in India |
| Temperature | 80 c |
The FireChem Swing Check Valve is a high-performance non-return valve (NRV) designed to ensure unidirectional flow in fire protection piping systems, preventing backflow and maintaining system integrity. Available in Flanged Swing Check Valve and Grooved Swing Check Valve configurations, it is widely used in firefighting systems, water distribution networks, and industrial pipelines.
Manufactured using robust ductile iron construction with corrosion-resistant epoxy coating, FireChem Swing Check Valves offer long service life, reliable sealing, and minimal pressure loss. The valve operates automatically using a swing-type disc mechanism, allowing fluid to flow in one direction while instantly preventing reverse flow.
Designed in compliance with international standards such as AWWA C508, UL 312, and FM Class 1210, these valves ensure dependable performance in critical fire protection applications.
Designed for high-pressure fire protection systems, this variant features ANSI / BS EN flanged connections for secure installation. Suitable for both horizontal and vertical pipelines, it ensures reliable backflow prevention in fire pump lines and main distribution systems.
Grooved Swing Check Valve (350 PSI)
Engineered for quick installation and maintenance, this variant comes with grooved end connections (AWWA C606 standard). Ideal for modular fire protection systems, it reduces installation time while maintaining high performance and reliability.
Key Features
• Prevents backflow in fire protection and water pipeline systems
• Available in flanged and grooved connection types
• Heavy-duty ductile iron body for durability
• Epoxy coated interior and exterior for corrosion resistance
• Low pressure drop and smooth flow characteristics
• Suitable for horizontal and vertical installation
• Automatic operation with swing-type disc mechanism
• Long service life with minimal maintenance
• Pressure Rating: 300 PSI (Flanged) / 350 PSI (Grooved)
• Testing Pressure: Up to 600 PSI / 700 PSI
• Temperature Range: Up to 80°C
• Sizes Available: 2” to 12”
• Standards: AWWA C508, UL 312, FM Class 1210
• Face-to-Face: As per ASME B16.10
• Coating: Epoxy coated (internal & external)
• Fire protection systems (hydrant & sprinkler lines)
• Fire pump discharge lines
• Industrial water pipelines
• Oil & gas facilities
• Petrochemical plants
• Power plants and utilities
• HVAC and infrastructure systems
• Available in multiple sizes (2” to 12”)
• Suitable for new installations and retrofit projects
• Compatible with fire protection systems and water supply networks
• Custom configurations available based on project requirements
Contact FireChem for technical datasheets, sizing assistance, and best commercial offers for your project requirements.
Get Latest Price
| System Type | Hydraulic |
| Control Signal | Automatic |
| No Of Valves | 1 Valve |
| Panel Type | Skid Mounted |
| Operating Pressure | Min: 2.1 BAR (30 PSI) / Max: 12 BAR (174 PSI) |
| Available Sizes | 25 NB, 40 NB, and 50 NB |
| Hydraulic Test Pressure | 18 BAR (261 PSI) for 2 Minutes |
| Body & Flange | ASTM A182 F304 (SS:304) |
The FireChem Hydraulic Foam Concentrate Control Valve is a critical safety component designed for seamless integration into bladder tank foam systems and inline balanced pressure proportioning systems. This valve is engineered to provide fail-safe automation, ensuring that foam concentrate is released into the system the moment water flow is detected. By operating purely on hydraulic pressure, it eliminates the need for electrical power, making it a highly reliable choice for remote or hazardous industrial locations.
The valve functions as an automatic gatekeeper for foam concentrate. It remains in a normally closed position under spring tension, preventing any accidental mixing or leakage of the concentrate.
Built with high-grade materials to ensure longevity and resistance to corrosive foam concentrates.
Available Sizes: 25 NB, 40 NB, and 50 NB
Operating Pressure: Min: 2.1 BAR (30 PSI) / Max: 12 BAR (174 PSI)
Hydraulic Test Pressure: 18 BAR (261 PSI) for 2 Minutes
Hydraulic Cylinder: Stainless Steel SS:304
Body & Flange: ASTM A182 F304 (SS:304)
Internal Components: Strainer, Ball Valve, and Hose all in SS:304
No Electrical Power Required: Ideal for areas where electronic components are at risk or where power may fail during an emergency.
Corrosion Resistant: Utilizing SS:304 for almost all major components, including the cylinder, mounting bracket, and piping, ensures the valve remains functional even in harsh environments.
Automatic Reset: The spring-loaded design ensures the valve closes automatically, protecting the remaining foam concentrate in the bladder tank after use.
Simplified Integration: Designed to work perfectly with Ratio Controllers, Alarm Valves, and Sprinkler Networks.
In a standard setup, the valve is installed on the foam concentrate discharge line from the bladder tank. The water inlet for the hydraulic cylinder is connected to the water supply side of the ratio controller. This configuration ensures that as soon as the water control valve opens, the foam concentrate is instantly and accurately metered into the sprinkler or foam solution network.
The FireChem Hydraulic Foam Concentrate Control Valve provides the peace of mind that comes with mechanical simplicity and robust engineering, ensuring your fire suppression system is always ready to act.
DP Parekh (CEO)
Fire Safety Devices Pvt. Ltd.
2nd Floor, B-4, Rama Palace, Near Ajronda - Sector 20b
Faridabad - 121007, Haryana, India